The Outdoor Plus Warranty, Care and Winterizing
The Outdoor Plus (TOP) warrants its fire pits, bowls and torches for 1 year against manufacturing defects, its stainless steel and aluminum pans for 5 years on residential installs, and its burner rings and burner bars for life. Electronics, gas valves and pilot assemblies are covered for 1 year at a home and 6 months on a commercial property. The warranty belongs to the original owner only and starts on the date of sale or shipment. What it does not cover matters just as much: natural weathering of copper and Corten, surface rust on stainless steel, electrodes and spark igniters, media, and damage from water, overheating, modification or improper installation. Keeping the unit covered and serviced yearly is the best protection for both the fire pit and the claim.
Warranty by part
| Part | Residential | Commercial |
|---|---|---|
| Burner ring and burner bars | Lifetime | Lifetime |
| Stainless steel and aluminum pans | 5 years | 1 year |
| Fire pits, bowls, fireplaces, Paradise Falls (GFRC, powder coat, stainless steel) | 1 year | 1 year |
| Electronics, gas valves and pilot assembly | 1 year | 6 months |
| Self-contained units; LED lighting | 1 year | 6 months |
| Torches; canvas covers; stainless steel covers | 1 year | 1 year |
| Glass wind guards | 1 year, cracking not covered | 1 year, cracking not covered |
The electronics, valve and pilot coverage applies when they were bought as part of a pan and burner kit or a complete fire feature. TOP ignitions must be installed on TOP products.
What is not covered
- Natural weathering of copper and Corten steel.
- Surface level rust on stainless steel.
- Electrodes and spark igniters, because of their lifespan.
- Ornaments and fire media, because of direct heat.
- Custom products and ready-to-finish products.
- Damage from water, overheating, modification, abuse, improper storage, installation or maintenance.
- Installation and maintenance labor, and damage by installers or movers.
- Any certified model that has been altered.
What voids coverage in practice
Short answer: skipping the manual's warranty requirements, which are mostly about enclosures, media and covers.
- A mesh or screen installed under the media.
- Filling the hollow space under the pan, or resting the unit's weight on the valve box instead of the pan.
- Daisy chaining the wiring of several electronic units instead of running each one separately.
- An electronic valve box set below grade or without drainage.
- Leaving the fire feature uncovered: TOP's spark ignition manual lists covering it when not in use as a warranty requirement.
- Lighting it with the cover or lid still on.
- Repairs by anyone other than a qualified technician.
How a warranty claim works
- Contact us with the order number, photos or video, and a description of the problem. Keep the original purchase information; TOP requires it.
- TOP can test a suspect component at its facility. If it is defective and in warranty, TOP repairs or replaces it and covers outgoing freight. If it is not defective, it is returned with no credit.
- A return needs a Return Merchandise Authorization from TOP, valid for 30 days, with the RMA number on the outside of the package and a copy inside. Pack it carefully; TOP is not responsible for damage in return shipping.
- Shipping errors or damage must be reported within 48 hours of delivery. Inspect before signing: see how freight delivery works.
TOP also has a product registration form on its website. Register after delivery so the purchase date is on file.
Care schedule
| When | What to do |
|---|---|
| Every use | Remove the cover or lid. Check the pan for debris and water. Look over the hose and connections on propane units. |
| After every use | Shut the gas off. Let it cool completely, then cover it. |
| Every six months | Check the electrode for corrosion; change batteries; clean soot from the thermocouple on flame sense and electronic systems. |
| Every year | Leak test with soapy water. Clean burner ports with a soft brush. Have a qualified gas technician inspect it; TOP suggests an NFI certified gas specialist. |
To clean the body, let it cool and rinse the enclosure with water, keeping the spray off the burner and igniter, then wipe dry. Material specific care is in the guides for Corten, copper, powder coat and stainless and GFRC concrete.
Winterizing
Short answer: gas off, dry, drained and covered.
- Turn the gas off at the source. On propane, close the tank and store spare cylinders outdoors, never in a garage or shed.
- Switch off power to electronic ignitions at the wall switch or breaker.
- Clear the pan and make sure vents and drain paths are open so water cannot pool and freeze.
- If lava rock is wet when you relight in spring, TOP says to let the fire burn 45 minutes before coming within 15 ft, because trapped moisture can make rock pop.
- Cover it with the canvas cover or a stainless steel lid once it is dry.
- TOP says not to use a unit if any part has been under water until a technician has inspected it.
More in fire pit maintenance and winterizing and fire feature warranties.
Frequently asked questions
Sources: The Outdoor Plus 2025 Product Warranty; TOP fire pit manual; Spark Ignition Safety Manual; Flame Sense with Spark Ignition System manual; Plug & Play to Low Voltage Pans & Burners manual. The paperwork that ships with your unit is what applies.
Have a problem with a The Outdoor Plus product you bought from us? Send the order number and photos and we will handle the claim with TOP.
Contact usTroubleshootingReviewed November 2026 by Fire Pit Supply. We check these guides against the current manufacturer documentation and update them when the specifications change.